ATS Pulmonary Function Laboratory Manual
chapter 17
11. McGovern JP, Sasse SA, Stansbury DW, Causing LA, Light RW. Comparison of oxygen satura- tion by pulse oximetry and co-oximetry during exercise testing in patients with COPD. Chest 1996;109:1151–1155. 12. Huch A, Huch R, König V, Neuman MR, Parker D, Yount J, Lübbers D. Limitations of pulse oxim- etry. Lancet 1988;1:357–358. 13. Ries AL, Prewitt LM, Johnson JJ. Skin color and ear oximetry. Chest 1989;96:287–290. 14. Brown M, Vender JS. Noninvasive oxygen monitoring. Crit Care Clin 1988;4:493–509. 15. Barker SJ, Shah NK. The effects of motion on the performance of pulse oximeters in volunteers (re- vised publication). Anesthesiology 1997;86:101–108. 16. Moran RF, Clausen JL, Ehrmeyer SS, Feil M, Van Kessel Al, Eichorn JH. Oxygen content, hemoglo- bin oxygen, “saturation,” and related quantities in blood: terminology, measurement, and reporting. National Committee for Clinical Laboratory Standards 1990;c25-P:10:1–49. 17. Schnapp LM, Cohen NH. Pulse oximetry: uses and abuses. Chest 1990;98:1244–1250. 18. Chapman KR, Liu FL, Watson RM, Rebuck AS. Range of accuracy of two wavelength oximetry. Chest 1986;89:540–542. 19. Severinghaus JW, Spellman MJ Jr. Pulse oximeter failure thresholds in hypotension and vasoconstric- tion. Anesthesiology 1990;73:532–537. 20. Chan MM, Chan MM, Chan ED. What is the effect of fingernail polish on pulse oximetry? Chest 2003;123:2163–2164. 21. Coté CJ, Goldstein EA, Fuchsman WH, Hoaglin DC. The effect of nail polish on pulse oximetry. Anesth Analg 1988;67:683–686. 22. Severinghaus JW, Naifeh KH. Accuracy of response of six pulse oximeters to profound hypoxia. An- esthesiology 1987;67:551–558. 23. Stoneham MD. Uses and limitations of pulse oximetry. Br J Hosp Med 1995;54:35–41. 24. Praud JP, Carofilis A, Bridey F, Lacaille F, Dehan M, Gaultier CL. Accuracy of two wavelength pulse oximetry in neonates and infants. Pediatr Pulmonol 1989;6:180–182. 25. Severinghaus JW, Naifeh KH, Koh SO. Errors in 14 pulse oximeters during profound hypoxia. J Clin Monit 1989;5:72–81. 26. Veyckemans F, Baele P, Guillaume JE, Willems E, Robert A, Clerbaux T. Hyperbilirubinemia does not interfere with hemoglobin saturation measured by pulse oximetry. Anesthesiology 1989;70:118–122. 27. Chelluri L, Snyder JV, Bird JR. Accuracy of pulse oximetry in patients with hyperbilirubinemia. Respir Care 1991;36:1383–1386. 28. Kim JM, Arakawa K, Benson KT, Fox DK. Pulse oximetry and circulatory kinetics associated with pulse volume amplitude measured by photoelectric plethysmography. Anesth Analg 1986;65:1333–1339. 29. Hornberger C, Matz H, Konecny E, Frankenberger H, Bonk R, Avgerinos J, Benekos K, Valais J, Ikiades A, Gil-Rodriguez J, et al. Design and validation of a pulse oximeter calibrator. Anesth Analg 2002;94(Suppl. 1):S8–S12. 30. Hansen JE, Casaburi R. Validity of ear oximetry in clinical exercise testing. Chest 1987;91:333–337. 31. Hutton P, Clutton-Brock T. The benefits and pitfalls of pulse oximetry. BMJ 1993;307:457–458. 32. Lawson D, Norley I, Korbon G, Loeb R, Ellis J. Blood flow limits and pulse oximeter signal detection. Anesthesiology 1987;67:599–603.
197
Made with FlippingBook Learn more on our blog